Sungrow Error Codes 

 

Below is a list of the various codes that may appear on your Sungrow inverter. We recommend restarting your inverter if any issues do arise. 

Just like restarting your computer, restarting your inverter can fix some common issues. 

These common issues include: 

  • Faults and errors that are displayed on the inverter (take note of these before restarting your inverter in case the error continues). These may relate to external factors like grid voltage or wiring
  • The system not communicating with internet monitoring (you may also need to restart your modem)
  • If the system is general not performing as it should

 

In the event that restarting your inverter doesn’t work, here is a list of what to do in the event of each Sungrow error code.

 

 
 Code  Meaning  What to do?
 0002

The grid voltage exceeds inverter allowable

upper limit.

Check the voltage of the grid.If the grid voltage exceeds the permissible range of inverter protection parameters, ask the utility grid company for a solution. If the grid voltage is within the permissible range, contact Sungrow Service Dept or Inspire Energy.
 0003

Grid transient voltage exceeds the permissible

range

This is a short-term fault due to grid condition. Inverter should fix itself. If the fault still appears, contact Inspire Energy
 0004

The grid voltage is below inverter’s allowable

lower limit.

Check the grid voltage.  If the grid voltage exceeds the permissible range of inverter protection parameters, ask the utility grid company for a solution. If the grid voltage is within the permissible range. If code continues to appear, contact Inspire Energy
 0005

The grid voltage is too low.

This is a short-term fault due to grid condition. Inverter should fix itself. If the fault still appears, contact Inspire Energy
 0006

The AC output current exceeds inverter allowable upper limit.

The inverter will resume if the output current falls below the protection value.  If the fault still appears, contact Inspire Energy
 0007

Transient AC overcurrent

The inverter will self-recover after several seconds. If the fault still exists, please contact Sungrow Service Dept.
 0008

The grid frequency exceeds inverter allowable upper limit.

Check the grid frequency. If the grid frequency exceeds the permissible range of inverter protection parameters, ask the utility grid company for a solution. If the grid frequency is within the permissible range, contact Sungrow Service Dept.
 0009

The grid frequency is below the inverter allowable lower limit.

 0010 Islanding Check whether AC circuit breaker is triggered, the cables are firmly connected. Check whether the grid is not in service. If all conditions are OK and this fault still occurs in the LCD screen, contact Inspire Energy
 0011

The DC component of AC current exceeds the inverter limit.

Inverter should fix itself but if the fault still appears, contact Inspire Energy
 0012

A failure current is detected.

Check the PV strings for ground fault. If the fault still appears, contact Inspire Energy
 0014

The average grid voltage exceeds the permissible range for over 10 minutes.

Wait a moment for inverter recovery. Check the voltage of the grid. If the grid voltage exceeds the permissible range of inverter protection parameters, ask the utility grid company for a solution. If the fault still appears, contact Inspire Energy
 0015

The grid voltage exceeds the permissible range

Check the model of the AC cables. The inverter should fix itself. Wait a moment for inverter recovery. If the grid voltage exceeds the permissible range of inverter protection parameters, contact Inspire Energy
 0016

The bus voltage or power is high.

Inverter should fix itself. If the fault still appears, contact Inspire Energy
 0019

The transient bus voltage is high.

 0020

The bus voltage is high.

 0021

PV1 input overcurrent is detected

Check the layout and the wiring of PV1 input.
 0022

PV2 input overcurrent is detected

Check the layout and the wiring of PV2 input.
 0036

The temperature of radiator is too high.

Check whether the placement of the inverter is correct. Check whether the inverter operating ambient temperature is more than the range. Check whether the AC output power exceeds the nominal power. If the fault still appears, contact Inspire Energy.
 0037 The internal temperature of inverter is too high
 0038

Relay fault is detected

Inverter should fix itself. If the fault still appears,  contact Inspire Energy
 039 The insulation resistance is low. (ISO-flt)

Check whether the positive and negative of PV panels is short-circuited with ground lead.

Inverter should fix itself. If the fault still appears, contact Inspire Energy

 041

Leakage current self-test abnormality

Inverter should fix itself. If the fault still appears,  contact Inspire Energy
 047

The PV configuration mode set in the phone application interface is not in accordance with the configuration in the connection cabinet.

Disconnect the inverter. Re-select PV configuration mode and re-connect PV strings.
 048

Sampling channel failure

Inverter should fix itself. If the fault still appears, contact Inspire Energy
 053

Auxiliary DSP detects grid voltage exceeds set protection value

Check the grid voltage. If the grid voltage exceeds the permissible range of inverter protection parameters, ask the utility grid company for a solution. If the fault still appears, contact Inspire Energy.
 054

Auxiliary DSP detects grid frequency exceeds set protection value

 056

Auxiliary DSP detects grid leakage current exceeds set protection range

Check whether there is a grounded fault of the PV string. If the fault still appears, contact Inspire Energy.
 057

Auxiliary DSP AC current sampling channel anomaly

Inverter should fix itself. If the fault still appears, contact Inspire Energy
 058

Auxiliary DSP detects AC current DC injection exceeds inverter set protection range

 059

Main and auxiliary DSP communication anomaly

 060

Main and auxiliary DSP sampling difference

 070

Fans are defective

Stop the inverter and disconnect the AC and DC cables. Check whether the fan duct has been blocked. If not, replace fans.
 087

Arc self-detection anomaly warn

Wait a while. Contact Inspire Energy.
 088 Arc anomaly fault Stop the inverter and disconnect the AC and DC cables. Check cable connection for aging and looseness. Re-power on and remove the arc warn manually. Contact Sungrow if this fault still occurs.
 089

Arc detection OFF warn

Remove the warn by enable arc detection function or keep the warn by closing arc detection function.
 100

The AC output current exceeds inverter

protection limit.

The inverter will resume if the output current falls below the protection value. If the fault still appears, contact Inspire Energy.
 101

The grid frequency exceeds inverter allowable upper limit.

Check the grid frequency. If the grid frequency exceeds the permissible range of inverter protection parameters, ask utility grid company for solution. If the grid frequency is within the permissible range, contact Inspire Energy
 102

The grid frequency is below the inverter allowable lower limit.

 106 The inverter is not grounded Check whether there is a reliable inverter grounding line, if there is access to the ground, and the fault still exists, please contact Sungrow Service Dept.
 200

The bus voltage is high.

Wait for inverter recovery after bus voltage lower.  If the fault still appears, contact Inspire Energy.
 201

The bus voltage is too low.

 202

PV current overcurrent

Wait for inverter recovery after DC current is reduced. If the fault still appears, contact Inspire Energy.
 205

AC output replay abnormal

Inverter should fix itself. If the fault still appears, contact Inspire Energy.
 307

DC power is too high

Check whether the configuration of PV is in the range indicated in the specification. If the fault occurs repeatedly, contact Sungrow Service Dept.